DESIGN AND CONSTRUCTION OF A SMOKE DETECTOR

DESIGN AND CONSTRUCTION OF A SMOKE DETECTOR
ABSTRACT

This project is titled design and construction of a smoke detector alarm. Fire/smoke alarm is an electronics device that is installed in a building to detect the presence of fire accident. Smoke detector alarm system is designed to detect the unwanted presence of fire by monitoring environmental changes associated with combustion. Smoke detector alarm systems are intended to notify the building occupants to evacuate in the event of a fire or other emergency, report the event to an off-premises location in order to summon emergency services, and to prepare the structure and associated systems to control the spread of fire and smoke.
This device constructed using a 555 timer circuit and a photo interrupter. The photo interrupter module is used as the smoke detector, while timer 555 is wired in astable configuration as an AF oscillator for sounding alarm via a loudspeaker.

TABLE OF CONTENTS

 TITLE PAGE

APPROVAL PAGE
DEDICATION
ACKNOWELDGEMENT
ABSTRCT
TABLE OF CONTENT

CHAPTER ONE

    1. INTRODUCTION
    2. AIM/OBJECTIVE OF THE PROJECT
    3. SIGNIFICANCE OF THE PROJECT
    4. SCOPE OF THE PROJECT
    5. LIMITATION OF THE PROJECT
    6. APPLICATION OF THE PROJECT
    7. PARTS OF FIRE ALARM
    8. PROJECT ORGANISATION

CHAPTER TWO

LITERATURE REVIEW
2.0      LITERATURE REVIEW OF SMOKE ALARM
2.1      REVIEW OF SMOKE DETECTOR
2.2     REVIEW OF TYPES OF FIRE ALARM SYSTEM
2.3      REVIEW OF FIRE ALARM DESIGN
2.4       REVIEW OF FIRE ALARM PARTS
2.5     REVIEW OF FIRE ALARM INITIATING DEVICES
2.6     FIRE ALARM NOTIFICATION APPLIANCES

 

CHAPTER THREE

3.0      CONSTRUCTION METHODOLOGY
3.1      BLOCK DIAGRAM OF THE SYSTEM
3.2      CIRCUIT DIAGRAM OF THE SYSTEM
3.3      CIRCUIT OPERATION OF THE SYSTEM
3.4      CIRCUIT DESCRIPTION OF THE SYSTEM
3.5      LIST OF COMPONENETS USED
3.5      POWER SUPPLY UNIT

CHAPTER FOUR

4.0       RESULT ANALYSIS

4.1      CONSTRUCTION PROCEDURE AND TESTING
4.2      ASSEMBLING OF SECTIONS
4.3      CONSRUCTION OF THE CASING
4.4     TESTING
4.5      ECONOMICS OF THE PROJECT
4.6      PROJECT EVALUATION
4.7      COST ANALYSIS

CHAPTER FIVE

5.1      CONCLUSIONS
5.2      RECOMMENDATION
5.3      REFERENCES

 

CHAPTER ONE
1.0                                                      INTRODUCTION
In modern society, it is impossible to imagine house or building without a fire accident detector. Modern houses require a continuous installation of fire detector. Not only industry, but also in the household. Take the case of a duplex that experience a fire accident without a detector that means everything in that building will get burnt even human beings. But in a case whereby fire alarm is installed that means every one in that building will be alerted and also fire security bodies will also be informed for quick security action. The same thing can also happen to our offices and industries. In order to notify residence of any building in the presence of fire accident, a fire alarm system is used.
An  fire detector alarm system is designed to detect the unwanted presence of fire by monitoring environmental changes associated with combustion. In general, a fire alarm system is classified as either automatically actuated, manually actuated, or both. Fire detector  alarm systems are intended to notify the building occupants to evacuate in the event of a fire or other emergency, report the event to an off-premises location in order to summon emergency services, and to prepare the structure and associated systems to control the spread of fire and smoke.
Commercial security detectors generates a signal to a fire alarm control panel as a part of a fire alarm system, where as household security detectors generally generates a buzzer sound from the detector itself. These detectors are kept in plastic enclosures and usually designed like a disk about 6 inches diameter and 1 inch in thickness, but size and shape can vary.
Smoke can be sensed either photoelectric or by ionization, smoke detectors may use either or both the methods. Smoke detectors are used in an industrial, residential and large commercial buildings are powered with a battery back up. The range of domestic smoke detectors are from individual powered battery units to various interlinked powered units with battery backup.
The aim of this project is to design and construct a fire alarm for a building that will detect the presence of fire accident in a building using 555 timer ic and a photo interrupter . The photo interrupter module is used as the smoke detector, while timer 555 is wired in astable configuration as an AF oscillator for sounding alarm via a loudspeaker.

    1. OBJECTIVE OF THE PROJECT

The aim of this project is to design and construct a fire alarm for a building that will detect the presence of fire accident in a building using 555 timer ic and a photo interrupter . The photo interrupter module is used as the smoke detector, while timer 555 is wired in astable configuration as an AF oscillator for sounding alarm via a loudspeaker.

1.2                               SIGNIFICANCE OF FIRE ALARM SYSTEM
The primary advantage of a home fire alarm system is increased reliability and the ability to place alarms and bells exactly where needed. However, the reason most people have them is that they wanted a burglar alarm system and the cost of adding fire alarm features to a residential burglary system is relatively small.
Another advantage is that they are the only way to obtain remote monitoring services. This becomes important in cases where family members may not be capable of escaping from a fire without assistance. For example, if you have an older or physically impaired person in your home and a fire started when no one was home to assist that person, alarms alone might not be enough to assure their safety.
A feature of most monitoring services is the ability to keep special information on the residence which comes up on the computer screen whenever an alarm is received from that home. Thus, if there is a disabled person in the home who needs special assistance this fact will be known to the operator and can be passed along to the fire department when they are called
1.3                                                   SCOPE OF THE WORK
This work is constructed using a 555 timer circuit and a photo interrupter . The photo interrupter module is used as the smoke detector, while timer 555 is wired in astable configuration as an AF oscillator for sounding alarm via a loudspeaker.
In the absence of any smoke, the gap of photo interrupter module is clear and the light from LED falls on the phototransistor through the slot. As a result, the collector of phototransistor is pulled towards ground. This causes reset pin 4 of IC 555 to go low. Accordingly, the timer is reset and hence the alarm does not sound.
When smoke is present in the gap of the photo interrupter module, the light beam from LED to the phototransistor is obstructed. As a result, the phototransistor stops conducting and pin4 (reset) of IC 555 goes high to activate the alarm.

1.4                                         APPLICATIONS OF THE PROJECT

Smoke detectors are suggested for a common use as they give the maximum level of protection. These devices can be used in leakage routes to offer sufficient early warning to let the clearing of residents.
There are two kinds of smoke detectors namely ionization and optical that are familiar as well general purpose detectors and they are accessible in both analogue addressable and conventional.
Ionization smoke detectors are highly sensitive to burn quickly and flaming fires that generate small smoke particles. These detectors are used widely for workshop printings, paint stores, paper mills and also used for general purpose
Optical smoke detectors are apt for detecting slow burning, fires smoldering which generate large smoke particles. These detectors are used in bedrooms, electrical switch rooms and escape corridors and also used for general purpose.

1.5                               PARTS OF FIRE ALARM
Fire alarm composed of the following parts:

  1. Primary Power supply: Commonly the non-switched 240 Volt Alternating Current source supplied from a commercial power utility. In non-residential applications, a branch circuit is dedicated to the fire alarm system and its constituents. “Dedicated branch circuits” should not be confused with “Individual branch circuits” which supply energy to a single appliance.
  2. Secondary (backup) Power supplies: This component, commonly consisting of sealed lead-acid storage batteries or other emergency sources including generators, is used to supply energy in the event of a primary power failure.
  3. Initiating Devices: This component acts as an input to the fire alarm control unit and are either manually or automatically actuated. Examples would be devices pull stations, heat detectors, or smoke detectors. Heat and smoke detectors have different categories of both kinds.

 

1.7 PROJECT WORK ORGANISATION
The various stages involved in the development of this project have been properly put into five chapters to enhance comprehensive and concise reading. In this project thesis, the project is organized sequentially as follows:
Chapter one of this work is on the introduction to smoke detector using photo interupter and 555 timers. In this chapter, the background, significance, objective limitation and problem of smoke detector using photo interupter and 555 timers were discussed.
Chapter two is on literature review of a smoke detector using photo interupter and 555 timers. In this chapter, all the literature pertaining to this work was reviewed.
Chapter three is on design methodology. In this chapter all the method involved during the design and construction were discussed.
Chapter four is on testing analysis. All testing that result accurate functionality was analyzed.
Chapter five is on conclusion, recommendation and references.

Download Full and Complete Project

About projectmaterial

Check Also

DESIGN AND CONSTRUCTION OF A HUMAN DETECTION ROBOT

DESIGN AND CONSTRUCTION OF A HUMAN DETECTION ROBOT Format: Ms Word Document Pages: 73 Price: …

DESIGN AND CONSTRUCTION OF A PASSWORD BASED CIRCUIT BREAKER

DESIGN AND CONSTRUCTION OF A PASSWORD BASED CIRCUIT BREAKER Format: Ms Word Document Pages: 73 …

DESIGN AND CONSTRUCTION OF EXPLOSIVE DETECTION SYSTEM

DESIGN AND CONSTRUCTION OF EXPLOSIVE DETECTION SYSTEM Format: Ms Word Document Pages: 73 Price: N …

DESIGN AND CONSTRUCTION OF DEAD MAN’S SWITCH

DESIGN AND CONSTRUCTION OF DEAD MAN’S SWITCH Format: Ms Word Document Pages: 73 Price: N …

DESIGN AND CONSTRUCTION OF BATTERY LEVEL INDICATOR

DESIGN AND CONSTRUCTION OF BATTERY LEVEL INDICATOR Format: Ms Word Document Pages: 73 Price: N …

DESIGN AND CONSTRUCTION OF A 3-PHASE IRRIGATION WATER PUMP CONTROLLER F USING DUAL GSM MODEMS

DESIGN AND CONSTRUCTION OF A 3-PHASE IRRIGATION WATER PUMP CONTROLLER F USING DUAL GSM MODEMS …

Leave a Reply

Your email address will not be published. Required fields are marked *